300W Inverter direct alarm and fault light on at power on
Model
BP series pure sine wave inverter 300W 48VDC 220VAC
Description
Alarm directly when starting, the fault light is on, and the buzzer sounds.
Analysis of the possibility of the cause
Checking the circuit board, it was found that the problem was caused by the rectifier bridge in the rear, and the fast recovery diode 1660CTA of the half bridge was damaged.
Solutions and steps
Replace the fast recovery diode.
Related Articles
4000 watt inverter working light and fault light on but no output after power on
Model BP series pure sine wave inverter 4000W 24VDC 220VAC Description No output, working light on, fault light on, buzzer sounding after power on. Analysis of the possibility of the cause Open the cover and check the internal components, 2 MOS tubes ...
BP3000W inverter on after the fault light flashes buzzer sound
Model BP series pure sine wave inverter 3000W 12VDC 110VAC Description After power on, the fault light flashedand buzzer sounded, and it could not work normally. Analysis of the possibility of the cause 1. Check the internal circuit to confirm that ...
BP600W inverter has no voltage output after power on but the fault light does not light up
Model BP series pure sine wave inverter 600W 12VDC 220VAC Description After power on, the fault light does not light up and there is no output voltage. Analysis of the possibility of the cause 1. Check the internal circuit, the rear part is damaged. ...
The fault light is on and the buzzer sounds after the 300W inverter is turned on
Model BP series pure sine wave inverter 300W 24VDC 220VAC Description After power on, the fault light is on, the buzzer sounds, and there is no output voltage. Analysis of the possibility of the cause 1. Check the internal components, the front and ...
BP 300W inverter fault light does not light up after power on but no output voltage
Model BP series pure sine wave inverter 300W 24VDC 220VAC Description Turn on normally, the fault light is off, but there is no output voltage. Analysis of the possibility of the cause After checking and replacing, it is determined that the rear ...