How will the inverter be affected if the input voltage is too high?
Model
BP series/BPlus series/Helios
Description
If the input voltage of battery exceeded defult value, capacitance will bulge/explode and further damage DC input part MOS tube.
Analysis of the possibility of the cause
The input voltage of DC battery was too high.
Solutions and steps
Change capacitance and MOS tube.
PS: Battery voltage of all models of inverter should not exceed values below:
B12P--15.5V、B24P--31V、B48P--62V
Related Articles
BP 300W inverter fault light does not light up after power on but no output voltage
Model BP series pure sine wave inverter 300W 24VDC 220VAC Description Turn on normally, the fault light is off, but there is no output voltage. Analysis of the possibility of the cause After checking and replacing, it is determined that the rear ...
No output voltage after the BP 600w inverter is turned on and the fault light flashes
Model BP series with bypass inverter 600W 12VDC 220VAC Description Can not be turned on normally, the fault light flashes after turning on, no output voltage. Analysis of the possibility of the cause 1. Check the internal circuit, the bus voltage is ...
The 2000W inverter output short circuit no response to power on
Model BP series pure sine wave inverter 2000W 12VDC 220VAC Description The customer describes the output short circuit, the inverter has no response when it is turned on, and there is no output voltage. Analysis of the possibility of the cause 1. ...
BP600W inverter has no voltage output after power on but the fault light does not light up
Model BP series pure sine wave inverter 600W 12VDC 220VAC Description After power on, the fault light does not light up and there is no output voltage. Analysis of the possibility of the cause 1. Check the internal circuit, the rear part is damaged. ...
Inverter is no output voltage after the customer has used it for a period of time
Model BP Series Pure Sine Wave Inverter 36VDC 220VAC 1000W Description There is no output voltage after the customer has used it for a period of time. Analysis of the possibility of the cause 1. The disassembly test found that there is no auxiliary ...