Burned inside the inverter of B12P300-2

Burned inside the inverter of 12VDC 300W

Model

BP Series Pure Sine Wave Inverter 12VDC 220VAC 300W


Description

1. Burned inside the inverter.

2. Disassembly test, found that the fuse is burnt, the front MOSFET is broken down, and the anti-reverse diode is broken down.


Analysis of the possibility of the cause

1. According to the test results, the fuse is burned out and the front-stage MOSFET is broken down, and the front-stage has a large current passing through it.

2. The anti-reverse diode is broken down, indicating that it is caused by the reverse connection of the DC terminal's positive and negative poles.


Solutions and steps

According to the analysis and judgment of the above two points, the front-end part is burnt due to the reverse connection of the positive and negative electrodes, and the machine is damaged and cannot be repaired.


    • Related Articles

    • Inverter no output of BP Series 3000W pure sine wave inverter

      Model BP series pure sine wave inverter 3000W 48VDC 220VAC Description Inverter no output Analysis of the possibility of the cause It's probably the battery voltage is too low. Solutions and steps Improve the power startup voltage. PS: The boot ...
    • No output of BP Series pure sine wave inverter 12VDC 220VAC 1000W

      Model BP series pure sine wave inverter 1000W 12VDC 220VAC Description Red and blue lights come on after startup. The machine has no output and the battery voltage is 12.7V. Analysis of the possibility of the cause The battery is short of voltage, ...
    • Continuous alarm on 4,000 watt pure sine inverter

      Model BP Series Pure Sine Wave Inverter 24VDC 120VAC 4000W Description turned on the inverter and found the alarm going on continuously. the output seems to be normal and there are no alarm lights or codes displayed so nothing showing any kind of an ...
    • No output after running 2-3 months of BP 2000 watt power inverter

      Model BP series pure sine wave inverter 2000W 12VDC 220VAC Description No output after using for 2-3 months, red and blue light are on at same time.  Analysis of the possibility of the cause 1.The ambient temperature and humidity of the inverter is ...
    • Inverter damaged AC output part mosfet caused by overload

      Model BPlus Series pure sine wave inverter Description The inverter still ran even after short circuit because of a full load in AC output, which damaged AC output part MOS tube. Fault Causes The inverter still overloaded after short ...