The 2000W inverter buzzer buzzes at intervals but the fault light is off
Model
BP Series Pure Sine Wave Inverter 24VDC 220VAC 2000W
Description
1. After the inverter is turned on, the working light is on, the fault light is off, there is no output voltage, and the buzzer buzzes at intervals.
2. Detect that the input voltage is normal, and the output is not connected to the load.
Analysis of the possibility of the cause
1. Open the cover and check, it is found that the work light of the rear board flashes after power on, unplug the temperature control line, restart the machine, and it is normal.
2. It is judged that the temperature control resistor has a short-circuit, which leads to over-temperature protection after the machine is turned on.
Solutions and steps
Replace the temperature control resistor that shown as the black wire. This one is connected to the radiator to detect the internal temperature.
Related Articles
Inverter 1000W buzzer buzzes and fault light on after power-on after starting
Model BP Series Pure Sine Wave Inverter 36VDC 220VAC 1000W Description 1. The buzzer buzzes and fault light on after power-on after starting. 2. Input battery voltage is normal. Analysis of the possibility of the cause 1.Confirmed that the front ...
6000W inverter buzzer buzzes without output after startup
Model BP series pure sine wave inverter 6000W 12VDC 220VAC Description After startup, there is no output, the fault light is on, and the buzzer buzzes. Analysis of the possibility of the cause After opening the cover for inspection, it was determined ...
BP3000W inverter on after the fault light flashes buzzer sound
Model BP series pure sine wave inverter 3000W 12VDC 110VAC Description After power on, the fault light flashedand buzzer sounded, and it could not work normally. Analysis of the possibility of the cause 1. Check the internal circuit to confirm that ...
The fault light is on and the buzzer sounds after the 300W inverter is turned on
Model BP series pure sine wave inverter 300W 24VDC 220VAC Description After power on, the fault light is on, the buzzer sounds, and there is no output voltage. Analysis of the possibility of the cause 1. Check the internal components, the front and ...
4000 watt inverter working light and fault light on but no output after power on
Model BP series pure sine wave inverter 4000W 24VDC 220VAC Description No output, working light on, fault light on, buzzer sounding after power on. Analysis of the possibility of the cause Open the cover and check the internal components, 2 MOS tubes ...