The 2000W inverter output short circuit no response to power on
Model
BP series pure sine wave inverter 2000W 12VDC 220VAC
Description
The customer describes the output short circuit, the inverter has no response when it is turned on, and there is no output voltage.
Analysis of the possibility of the cause
1. Check the internal components, 10 of the 12 front MOSfets are damaged, 2 of the rear MOSfets are damaged, and the rear driver board is damaged.
2. Because there is no specific on-site situation, it is impossible to confirm the specific cause of the failure. After replacing all damaged components, the inverter runs normally.
Solutions and steps
The customer cancels the maintenance request due to the high maintenance cost.
Related Articles
BP 300W inverter fault light does not light up after power on but no output voltage
Model BP series pure sine wave inverter 300W 24VDC 220VAC Description Turn on normally, the fault light is off, but there is no output voltage. Analysis of the possibility of the cause After checking and replacing, it is determined that the rear ...
No output voltage after the BP 600w inverter is turned on and the fault light flashes
Model BP series with bypass inverter 600W 12VDC 220VAC Description Can not be turned on normally, the fault light flashes after turning on, no output voltage. Analysis of the possibility of the cause 1. Check the internal circuit, the bus voltage is ...
BP600W inverter has no voltage output after power on but the fault light does not light up
Model BP series pure sine wave inverter 600W 12VDC 220VAC Description After power on, the fault light does not light up and there is no output voltage. Analysis of the possibility of the cause 1. Check the internal circuit, the rear part is damaged. ...
No output after running 2-3 months of BP 2000 watt power inverter
Model BP series pure sine wave inverter 2000W 12VDC 220VAC Description No output after using for 2-3 months, red and blue light are on at same time. Analysis of the possibility of the cause 1.The ambient temperature and humidity of the inverter is ...
The fault light is on and the buzzer sounds after the 300W inverter is turned on