The external small power fan causes the 3000 watt inverter to burn out due to high temperature
Model BPlus series pure sine wave inverter 3000W 48VDC 110VAC Description Because it was a bare machine, the customer configured the fan himself, fan was low power and the air duct was blocked, the temperature was too high in a short period of time ...
The BPlus series 2000W inverter startup normal and not alarm but has no output voltage
Model BPlus Series Pure Sine Wave Inverter 48VDC 110VAC 2000W Description The startup is normal, the inverter does not alarm, but there is no output voltage. Analysis of the possibility of the cause The test of the auxiliary power supply part is ...
Output voltage is unsteady of BPlus Series 300W inverter
Model BPlus series pure sine wave inverter 300W 12VDC 220VAC Description The inverter can be started up but its output voltage is unsteady. Analysis of the possibility of the cause R18 resistance in bus voltage has been damaged, the transient ...
Inverter damaged AC output part mosfet caused by overload
Model BPlus Series pure sine wave inverter Description The inverter still ran even after short circuit because of a full load in AC output, which damaged AC output part MOS tube. Fault Causes The inverter still overloaded after short ...
Display not same actual situation of BPlus 2000W inverter
Model BPlus series pure sine wave inverter 2000W 12VDC 120VAC Description 1. DC input voltage 11.3V, input current 0.2167A. But the data shown on inverter display is inconsistent with the actual situation. As shown in figure 1. 2. Theoretically, the ...
BPlus-3000W inverter will restart when it loaded with 1.6KW
Model BPlus Series Pure Sine Wave Inverter 3000W Description When BPlus-3000W is loaded with 1.6KW, it will restart in about 4 minutes. Analysis of the possibility of the cause After inspection, it is found that the user uses a low-quality DC circuit ...
Portable power supply turned on inverter damage
Model BPlus Series Pure Sine Wave Inverter 36VDC/1000W/220VAC Description B36P1000-2 which integrated into the portable power supply will be damaged when it is turned on. Analysis of the possibility of the cause 1. When checking the usage status of ...